How to Winterize a Hayward Pool Pump: Complete Guide

Winterising a Hayward pool pump prevents freeze damage during cold months when temperatures drop below freezing. Water expands approximately 9% when freezing, creating pressure that cracks pump housings, filter tanks, plumbing lines, and heater components. Proper winterisation drains all water from equipment, protecting your investment from costly repairs and ensuring reliable operation when reopening the pool in spring.

This comprehensive guide covers step-by-step winterisation procedures for Hayward pool pumps, filters, heaters, and related equipment. Whether you experience harsh northern winters or occasional freeze events, understanding proper drainage techniques, plug removal, and freeze protection strategies safeguards equipment and extends lifespan.

Key Takeaways

  • Freeze damage occurs at 0°C (32°F) – water expands when freezing, cracking pump housing, filter tanks, and pipes.
  • Drain all water completely – remove drain plugs from pump, filter, heater; blow out plumbing lines.
  • Store drain plugs safely – keep plugs in labelled bag or pump basket for spring reinstallation.
  • Lower pool water below skimmers – prevents water from entering equipment through return lines.
  • Use pool antifreeze in lines – non-toxic propylene glycol protects plumbing (never automotive antifreeze)
  • Freeze protection mode – Hayward controllers automatically run pumps when temperatures approach freezing (if power available)
  • Indoor storage option – remove pump/filter and store indoors in severe winter climates

Why Winterise a Hayward Pool Pump?

Freeze Damage Prevention

Water freezing inside pump housing, filter tanks, heater heat exchangers, or plumbing pipes creates expansion pressure exceeding material strength. Common freeze damage includes:

Pump housing cracks: Ice splits pump body at seams, volute, or impeller housing — repair cost €300-800 or complete pump replacement.

Filter tank damage: Frozen water cracks sand filter tanks (particularly older fibreglass models), DE filter grids, or cartridge filter housings = replacement €400-1,200.

Heater heat exchanger failure: Ice destroys copper or titanium heat exchanger tubes = repair €600-2,000, often totalling the heater.

Pipe bursts: Underground PVC plumbing cracks from ice expansion = requires excavation, pipe replacement, concrete repair.

Valve damage: Frozen water breaks multiport valves, check valves, ball valves = replacement €80-300 per valve.

Cost Savings

Proper winterisation (1-3 hours labour, minimal cost) prevents thousands in freeze damage repairs. Insurance often excludes freeze damage classified as preventable maintenance failure.

Extended Equipment Lifespan

Eliminating freeze-thaw cycles reduces material stress on pump seals, filter components, and plumbing connections, extending equipment life 20-30%.

When to Winterise

Temperature Guidelines

Immediate winterisation required: When daytime highs remain below 10°C (50°F), and nighttime lows approach 0°C (32°F).

Pre-emptive winterisation recommended: Before the first predicted freeze if not using freeze protection mode.

Mild climate consideration: Even regions with rare freezing (Texas, southern US, southern Europe) require winterisation preparation as unexpected cold snaps cause significant damage.

Seasonal Timing

Northern climates (regular freezing): October-November before sustained below-freezing temperatures.

Transitional climates (occasional freezing): Late November-December, monitoring weather forecasts.

Mild climates (rare freezing): Prepare winterisation procedure in advance; execute when freeze warning is issued.

Tools and Materials Needed

Required Equipment

  • Phillips and flathead screwdrivers
  • Adjustable wrench or socket set
  • Shop vacuum (wet/dry) or air compressor with pressure regulator
  • Garden hose
  • Buckets or containers for draining water
  • Towels or rags
  • Pool antifreeze (non-toxic propylene glycol, 3-5 gallons typical)
  • Threaded winter plugs or expansion plugs for return lines
  • Skimmer guard or gizmo (absorbs ice expansion in skimmer)
  • Labelled plastic bags for storing drain plugs
  • Breathable equipment covers (avoid solid tarps trapping moisture)
  • Teflon tape

NEVER use automotive antifreeze. Ethylene glycol is toxic, damages pool components, and contaminates pool water.

Step-by-Step Winterisation: Hayward Pool Pump

Step 1: Turn Off All Power

Safety first: Shut off power at the circuit breaker panel serving pool equipment. Tag breaker with “WINTERIZED – DO NOT TURN ON” label.

Verify power off: Confirm pump does not respond to control panel or manual switches.

Caution: Attempting winterisation with power risks equipment damage and personal injury.

Step 2: Lower Pool Water Level

Target level: 10-20 cm (4-8 inches) below skimmer opening and return jet fittings.

Method: Use pool pump on “waste” setting or submersible pump to drain.

Reason: Water above skimmer level can flow back into equipment through return lines, refilling drained pump/filter.

Do not drain the pool completely unless required by specific winterisation strategy or pool type. Excessive draining can cause structural issues (vinyl liner wrinkles, concrete pool lifting from groundwater pressure).

Step 3: Clean Pool and Equipment

Skim debris: Remove leaves, dirt, and organic matter from pool surface and bottom.

Brush walls and floor: Dislodge algae and biofilm.

Clean skimmer and pump baskets: Remove accumulated debris.

Backwash filter: Sand and DE filters should be backwashed until water runs clear; cartridge filters removed and rinsed.

Reason: Organic matter decomposing during winter creates unpleasant odours, stains surfaces, and increases spring cleaning workload.

Step 4: Balance Water Chemistry

Test and adjust water several days before closing:

  • pH: 7.4-7.6
  • Total alkalinity: 80-120 ppm
  • Calcium hardness: 200-400 ppm
  • Chlorine: 1-3 ppm

Add shock treatment: Superchlorinate the pool (triple normal dose) to kill bacteria and oxidise organic contaminants.

Optional winter chemicals: Algaecide and winter chemical kit prevent algae growth during dormancy.

Reason: Balanced chemistry prevents corrosion and scale formation during months of stagnation.

Step 5: Drain Hayward Pump

Location of drain plugs: Hayward pumps typically have two drain plugs on the bottom of the pump housing (strainer body).

Procedure:

  1. Remove pump strainer lid (twist counterclockwise and lift)
  2. Remove pump basket
  3. Locate drain plugs on the underside of the pump housing, typically one on each side of the impeller chamber.
  4. Use a flathead screwdriver or appropriately sized socket to unscrew drain plugs (turn counterclockwise)
  5. Allow all water to drain from the pump housing and tilt the pump gently if necessary to ensure complete drainage.
  6. Check for residual water in pump basket cavity and remove with towel or wet/dry vacuum.

Store drain plugs: Place removed plugs in a pump basket or labelled plastic bag. Write “PUMP DRAIN PLUGS” on the bag. Store in a visible location (on top of covered pump, in equipment area) for easy spring retrieval.

Leave plugs out all winter and do not reinstall until spring startup.

Step 6: Remove Pump Strainer Lid O-Ring (Optional)

Remove and clean: Take the pump lid O-ring seal off, clean with water, dry, and coat lightly with silicone-based lubricant.

Storage: Place the O-ring in a plastic bag inside the pump basket to prevent drying and cracking during winter.

Reason: Extended compression under pump lid during months of inactivity can cause permanent o-ring deformation, leading to air leaks when reopening the pool.

Step-by-Step Winterisation: Filter

Sand Filters

Multiport valve setting: Set valve to “winterise” position (if available) or leave on “filter” position with valve open.

Drain plug location: Bottom centre of filter tank.

Procedure:

  1. Open air relief valve on top of filter (turn counterclockwise or lift handle)
  2. Remove drain plug from bottom of tank
  3. Allow water to drain completely (may take 15-30 minutes for large filters)
  4. Leave air relief valve and drain plug removed all winter

Backwash valve: Leave multiport valve drain port open to allow any residual water drainage.

Store drain plug: Place in labelled bag or pump basket.

Sand replacement: If filter sand is 5-7 years old, winter is an ideal time to schedule spring sand replacement.

DE (Diatomaceous Earth) Filters

Drain plug location: Bottom of filter tank.

Procedure:

  1. Backwash filter to remove old DE coating
  2. Remove filter tank top or open access panel
  3. Open air relief valve
  4. Remove bottom drain plug
  5. Inspect grids for tears or damage and replace damaged grids before spring
  6. Allow tank to drain completely
  7. Leave tank partially disassembled (top off or access panel open) for ventilation during winter.

Grid removal option: Remove grids, clean thoroughly, inspect, and store indoors in dry locations.

Cartridge Filters

Drain plug location: Bottom of filter tank.

Procedure:

  1. Open air relief valve
  2. Remove drain plug from bottom of tank
  3. Open filter tank (unscrew lid or release clamp band)
  4. Remove cartridge(s)
  5. Clean cartridges thoroughly with hose or cartridge cleaner
  6. Inspect for tears, crushed pleats, worn end caps and replace damaged cartridges
  7. Allow tank and cartridges to dry completely
  8. Store cartridges in a dry, rodent-free location OR reinstall in tank if stored outdoors

Tank storage: Leave filter tank open or lid propped partially open for ventilation, preventing moisture buildup and mildew.

Step-by-Step Winterisation: Heater

Gas and Electric Heaters

Power/gas shutoff: Turn off the electrical breaker and close the gas supply valve.

Drain plug location: Bottom of heat exchanger or header (varies by model, so consult a manual).

Procedure:

  1. Allow heater to cool completely (15-20 minutes after last operation)
  2. Turn off gas supply at heater and main shutoff
  3. Turn off electrical power at breaker
  4. Locate and remove drain plug(s), as there are typically one or two plugs at the lowest point of the heat exchanger.
  5. Open pressure relief valve if equipped
  6. Tilt heater slightly toward drain plug side to ensure complete drainage (if possible)
  7. Inspect burner assembly and heat exchanger for corrosion or damage

Rodent protection: Place mesh screen over heater vents and air intake to prevent nesting during winter. Rodents often nest in warm, protected heater cabinets, causing significant damage.

Store drain plugs: Label and store with other equipment plugs.

Heat Pumps

Specific Hayward heat pump procedure (consult model-specific manual):

  1. Turn off power supply at breaker
  2. Disconnect union fittings on water inlet and discharge lines
  3. Remove drain plug from heat exchanger (location varies by model)
  4. Tilt heat pump slightly toward fittings to ensure complete drainage from heat exchanger
  5. Clean condenser coil fins with a soft brush or water spray
  6. Cover heat pump with breathable cover (avoid solid plastic tarps that trap moisture)

Heat pumps are sensitive to moisture. Ensure complete drainage to prevent internal component damage.

Blow Out Pool Plumbing Lines

Why Blow Out Lines

Draining the pump, filter, and heater removes water from equipment, but plumbing lines (pipes connecting pool to equipment) retain water. Underground PVC pipes hold water in low spots, creating freeze risk.

Equipment Needed

Air compressor or shop vacuum: Minimum 5-10 PSI for above-ground lines; 15-20 PSI for underground plumbing.

Adapters: Threaded fittings to connect compressor/vacuum hose to skimmer or pump drain plug opening.

Procedure

Skimmer lines:

  1. Connect air compressor to skimmer opening or pump drain plug port
  2. Start air flow at low pressure (5-10 PSI)
  3. Watch for bubbles emerging from main drain and return lines in pool
  4. Continue airflow for 2-3 minutes after steady bubbles are visible
  5. Immediately plug return lines with threaded winter plugs or expansion plugs
  6. Install skimmer guard (gizmo) in skimmer which absorbs ice expansion, prevents skimmer cracking

Return lines:

  1. Blow air from equipment pad toward pool
  2. Watch for bubbles at return jets
  3. Once air flows steadily, install threaded plugs in return jet openings (from inside pool)

Main drain line:

  1. Blow air through main drain line until bubbles emerge from main drain
  2. Main drain typically left open (does not require plug)

Caution: Do not exceed 20 PSI air pressure. It can damage plumbing fittings and seals.

Add Pool Antifreeze

When to Use Antifreeze

Underground plumbing: After blowing out lines, add pool antifreeze as additional protection.

Skimmers: Pour antifreeze into the skimmer after installing skimmer guard.

Exposed above-ground plumbing: Flexible hoses, connections near equipment.

Proper Pool Antifreeze

Type: Non-toxic propylene glycol formulated for pools.

Quantity: 1 gallon per 10 linear feet of plumbing (approximate).

Application:

  • Pour antifreeze into the skimmer until it flows into underground lines
  • Add antifreeze to each return line if not completely blown out
  • Pour small amount into pump and filter if any residual water suspected

NEVER use automotive antifreeze (ethylene glycol) as it’s toxic to humans and animals, corrodes pool equipment, and contaminates pool water.

Additional Winterisation Steps

Chlorinator/Salt Cell (Saltwater Pools)

Salt chlorine generators: Remove cells from plumbing, clean off calcium deposits, store indoors in climate-controlled locations.

Inline chlorinators: Remove chlorine tablets, drain water, remove lid, store indoors.

Automatic Pool Cleaners

Suction-side cleaners: Remove from pool, drain water, store indoors.

Pressure-side cleaners: Remove from pool, disconnect booster pump (drain and remove drain plugs), store cleaner indoors.

Robotic cleaners: Remove from pool, rinse thoroughly, allow to dry, store indoors in a dry location.

Pool Cover

Safety cover: Install over pool surface, secured with anchors around perimeter. Prevents debris accumulation, provides safety barriers, eliminates need for water tubes.

Winter mesh cover: Install with water tubes or weights around the edge. Allows rain/snow melt to pass through, preventing water accumulation.

Solid cover with air pillow (above-ground pools): Place air pillow in centre of pool, install cover over top, secure with cable and winch. The air pillow creates a peak directing ice expansion inward (away from pool walls).

Freeze Protection Mode (Alternative to Full Winterisation)

What is Freeze Protection?

Hayward OmniLogic, ProLogic, and AquaPlus controllers include automatic freeze protection mode. When the air temperature sensor detects temperature approaching freezing (typically 1-2°C / 34-36°F), the controller automatically activates the pump to circulate water continuously, preventing pipe freeze.

How It Works

Temperature threshold: Programmable, typically set at 1-2°C (34-36°F).

Pump operation: Runs at full speed continuously while the temperature is below the threshold.

Dual-body systems: Alternates between pool and spa every 30 minutes to protect both plumbing systems.

Duration: Continues until temperature rises above threshold (typically 2-3°C / 36-38°F).

When to Use Freeze Protection Instead of Winterisation

Mild climates with occasional freezes: Southern US, Mediterranean regions, coastal areas with rare brief freezes.

Pools used year-round: Heated pools where the owner desires continued operation despite occasional cold weather.

Reliable power supply: Freeze protection requires continuous electricity – power outages eliminate protection.

Limitations

Power outage vulnerability: If power fails during a freeze event, equipment is at risk without manual winterisation backup.

Energy costs: Running the pump continuously during freeze periods increases electricity consumption (€5-15 per freeze event depending on duration).

Does not replace full winterisation: In climates with sustained below-freezing temperatures (weeks or months), freeze protection is insufficient – pump cannot prevent freeze in long-term extreme cold.

Emergency Freeze Protection (Power Outage During Freeze)

If Power Fails During Freezing Weather

Immediate action required to prevent equipment damage:

  1. Turn off all equipment breakers – prevents pump from starting without water when power is restored
  2. Remove all drain plugs immediately – pump, filter, heater
  3. Open air relief valves – filter air bleeder, any other pressure relief points
  4. Open plumbing valves – close pool valves, open equipment bypass valves to drain standing water
  5. Pour pool antifreeze – into skimmer, pump, filter if available
  6. Cover equipment – heavy blankets or insulated covers to slow temperature drop

If Equipment Already Frozen

Do not turn on power – frozen water prevents proper operation, causing further damage.

Allow natural thawing: Place heavy blankets over equipment, allow ambient temperature rise to thaw naturally (24-48 hours).

Optional: A small space heater inside a blanket “tent” around equipment accelerates thawing. Monitor constantly to prevent fire hazard.

Inspect thoroughly after thawing: Check pump housing, filter tank, heater, pipes for cracks before restoring power.

Spring Startup After Winterisation

Reinstallation Checklist

  1. Reinstall all drain plugs – pump (both plugs), filter, heater, any other equipment.
  2. Reinstall pump lid O-ring – ensure proper seating
  3. Remove winter plugs from return lines – extract threaded plugs from jets
  4. Remove skimmer guard – take out gizmo from skimmer
  5. Refill pool – bring water level back to midpoint of skimmer opening
  6. Prime pump – fill pump strainer basket with water, install lid, open skimmer valves
  7. Restore power – turn on breaker
  8. Start pump – monitor for leaks, proper priming, normal operation
  9. Rebalance water chemistry – test and adjust all parameters
  10. Reinstall salt cell, chlorinator, automatic cleaner – reconnect all removed equipment

Storage Option: Remove Equipment Indoors

When to Remove Equipment

Extreme cold climates: Regions with sustained sub-zero temperatures, heavy snow, ice accumulation.

Valuable equipment: New or expensive pumps, variable-speed pumps, heaters.

Moisture-sensitive components: Electronic controls, heat pump compressors.

What to Remove

Pump and motor: Disconnect plumbing unions, remove entire unit, store in dry basement, garage, or shed.

Filter tank (optional): Above-ground cartridge filters can be removed; large sand/DE filters typically left in place.

Heater (rarely): Most heaters remain installed, and removing them disconnects gas lines and electrical, creating spring reinstallation complexity.

Salt cell: Always remove and store indoors (prevents calcium scaling, protects electronic components).

Automatic cleaner and booster pump: Remove and store indoors.

Storage Conditions

Dry, ventilated space: Prevents moisture accumulation causing mildew and corrosion.

Above freezing: Protects rubber seals, gaskets, and O-rings from brittleness.

Rodent-free: Mice and rats nest in pump cavities, chewing wires and seals.

Common Winterisation Mistakes

Mistake 1: Leaving Drain Plugs Installed

Problem: Trapped water freezes, cracks the pump housing and filter tank despite lowering pool water level.

Solution: Always remove ALL drain plugs, including pump (both), filter, and heater.

Mistake 2: Not Blowing Out Plumbing Lines

Problem: Water remains in underground pipes, freezes, and cracks PVC.

Solution: Use an air compressor to blow out all lines; add pool antifreeze.

Mistake 3: Using Automotive Antifreeze

Problem: Ethylene glycol is toxic, corrodes equipment, and contaminates pool water.

Solution: Only use pool-grade non-toxic propylene glycol antifreeze.

Mistake 4: Draining Pool Completely

Problem: Empty concrete pools can lift from groundwater pressure; vinyl liners wrinkle and deteriorate.

Solution: Lower water 10-20 cm below skimmer, never drain completely unless specific need.

Mistake 5: Forgetting Equipment Stored Indoors

Problem: Pump, salt cell, or cleaner are stored indoors but forgotten, which brings delays to the spring opening.

Solution: Label stored equipment clearly, keep it in a visible location, create a reinstallation checklist.

Conclusion

Winterising a Hayward pool pump protects against freeze damage by completely draining water from pump housing (removing both drain plugs), filter tank (opening the air relief and bottom drain plug), heater (draining the heat exchanger), and plumbing lines (blowing out with an air compressor). Proper winterisation prevents water expansion during freezing from cracking equipment, avoiding repair costs of €300-2,000+ per damaged component.

Critical steps include turning off all power, lowering pool water below skimmers, removing all drain plugs and storing them safely, blowing out plumbing lines, adding non-toxic pool antifreeze to pipes, and installing winter plugs in return lines. In mild climates with occasional freezes, Hayward’s freeze protection mode provides automated pump operation during cold weather as an alternative to full winterisation, though this requires a reliable power supply.

Spring startup reverses the process: reinstall all drain plugs, remove winter plugs from return lines, refill pool to proper level, prime pump, restore power, and rebalance water chemistry. Following manufacturer guidelines and completing all steps thoroughly ensures equipment operates reliably for years, protecting your investment through countless freeze-thaw cycles while providing peace of mind during winter dormancy.

FAQ

How do I winterise my Hayward pool pump?

Turn off power, then open the pump lid and remove the drain plugs to empty all water. Blow out lines if needed, and store the plugs in the pump basket. In freezing climates, cover or bring the pump indoors if possible.

Should the Hayward salt cell be removed for winter?

Yes, it’s recommended. Remove the salt cell, clean it, and store it indoors in a dry place. This helps prevent freezing damage and extends the life of the cell during the off-season.

Do Hayward pumps have freeze protection?

Some newer Hayward variable-speed pumps have built-in freeze protection that automatically runs the pump at low speed when temperatures drop. However, it’s not a substitute for full winterisation in cold climates.

How to drain water from a Hayward pool pump?

Turn off the system, locate the drain plugs at the bottom of the pump housing, and remove them to let water flow out. Open the pump lid to allow air in so it drains completely, preventing freeze damage.